SIMATIC S7-300,INTERFACE MODULE IM174, FOR CONNECTING ANALOG DRIVES AND STEP DRIVES VIA ISOCHRONUS PROFIBUS TO MOTION CONTROLLERS 4 CHANNELS (4 ENCOD.INP., 4 AO) CONFIGURABLE WITH STEP7 V5.4 SP4 |
|
Supply voltage |
24 V DC |
Yes |
permissible range, lower limit (DC) |
20.4 V |
permissible range, upper limit (DC) |
28.8 V |
Input current |
Current consumption, max. |
500 mA |
from backplane bus 5 V DC, max. |
100 mA |
Encoder supply |
5 V encoder supply |
5 V |
Yes |
Output current, max. |
1.2 A |
Cable length, max. |
25 m |
24 V encoder supply |
24 V |
Yes |
Output current, max. |
1.4 A |
Cable length, max. |
100 m |
Absolute encoder (SSI) encoder supply |
Absolute encoder (SSI) |
Yes |
Short-circuit protection |
Yes |
Power loss |
Power loss, typ. |
12 W |
Digital inputs |
Number of digital inputs |
10 |
Input voltage |
for signal "0" |
-3 to +5 V |
for signal "1" |
11 to 30 V |
Input current |
for signal "0", max. (permissible quiescent current) |
2 mA |
for signal "1", typ. |
8 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
at "0" to "1", min. |
15 µs |
Cable length |
Cable length, shielded, max. |
100 m |
Digital outputs |
Number of digital outputs |
8 |
Short-circuit protection |
Yes |
Switching capacity of the outputs |
with resistive load, max. |
1 A |
on lamp load, max. |
30 W |
Lamp load, max. |
30 W |
Output voltage |
Rated value (DC) |
24 V; L+ |
for signal "1", min. |
L+ (-3 V) |
for signal "1", max. |
3 V |
Output current |
for signal "1" permissible range for 0 to 55 °C, min. |
5 mA |
for signal "1" permissible range for 0 to 55 °C, max. |
300 mA |
for signal "0" residual current, max. |
0.4 mA |
Output delay with resistive load |
"0" to "1", max. |
500 µs |
Switching frequency |
with resistive load, max. |
500 Hz |
with inductive load, max. |
0.5 Hz |
Relay outputs |
Number of relay outputs |
4 |
Number of operating cycles, max. |
50000 |
Switching capacity of contacts |
with resistive load, max. |
1 A |
Cable length |
Cable length, shielded, max. |
600 m |
Analog outputs |
Number of analog outputs |
4 |
Output ranges, voltage |
-10 to +10 V |
Yes |
Analog value generation |
Integration and conversion time/resolution per channel |
Resolution with overrange (bit including sign), max. |
15 bit |
Encoder |
Number of connectable encoders, max. |
4 |
Connectable encoders |
Incremental encoder (symmetrical) |
Yes |
Absolute encoder (SSI) |
Yes |
2-wire sensor |
Yes |
permissible quiescent current (2-wire sensor), max. |
2 mA |
Encoder signals, incremental encoder (symmetrical) |
Trace mark signals |
A, notA, B, notB |
Zero mark signal |
N, notN |
Input signal |
5 V difference signal (phys. RS 422) |
Input frequency, max. |
1 MHz |
Cable length, shielded, max. |
35 m; 35 m at max. 500 kHz; 10 m at max. 1 MHz |
Encoder signals, absolute encoder (SSI) |
Input signal |
5 V difference signal (phys. RS 422) |
Data signal |
DATA, notDATA |
Clock signal |
CL, notCL |
Telegram length, parameterizable |
13, 21, 24 bit |
Clock frequency, max. |
1.5 MHz; 187.5 KHz 1.5 MHz (parameterizable) |
Binary code |
1 |
Gray code |
1 |
Cable length, shielded, max. |
250 m; 250 m at 187.5 kHz, 10 m at 1.5 MHz |
Isochronous mode |
Isochronous mode (application synchronized up to terminal) |
Yes |
shortest clock pulse |
1.5 ms |
Interrupts/diagnostics/status information |
Alarms |
Diagnostic alarm |
Yes |
Drive interface |
Number of drive interfaces |
4 |
Analog drive |
Setpoint signal |
Short-circuit proof |
Yes; max. 45 mA, min. 3.3 kOhm load impedance |
Rated voltage range |
-10.5 V to +10.5 V |
Output current |
-3 to +3 mA |
Output controller enable |
Number of relay contacts |
4 |
Switching voltage, max. |
30 V |
Switching current, max. |
1 A |
Switching capacity, max. |
30 V·A |
Number of switching cycles, min. |
50000; at 30 V DC, 1 A |
Cable length (shielded), max. |
35 m |
Signal output I |
Number of relay contacts |
2 |
Switching voltage, max. |
30 V |
Switching current, max. |
1 A |
Switching capacity, max. |
30 V·A |
Number of switching cycles, min. |
50000; at 30 V DC, 1 A |
Cable length (shielded), max. |
35 m |
Signal output II |
Differential output voltage, min. |
2 V; R = 100 Ohm |
Differential output voltage for signal "1", min. |
3.7 V; 3.7 V at I = -20 mA; 4.5 V at I = -100 µA, |
Differential output voltage for signal "0", max. |
1 V; For I = -20 mA |
Load resistance, min. |
55 Ω |
Output current, max. |
60 mA |
Signal output III |
Pulse frequency |
750 kHz |
Cable length (shielded), max. |
50 m; in hybrid operation with analog axes 35 m, in asymmetrical transmission 10 m |
Galvanic isolation |
Galvanic isolation digital inputs |
Galvanic isolation digital inputs |
Yes; to encoders, analog outputs, DP interface; no to other DI/DOs |
Galvanic isolation digital outputs |
Galvanic isolation digital outputs |
Yes; to encoders, analog outputs, DP interface; no to other DI/DOs |
Degree and class of protection |
IP20 |
Yes |
Ambient conditions |
Operating temperature |
min. |
0 °C |
max. |
55 °C |
Storage/transport temperature |
min. |
-40 °C |
max. |
70 °C |
Relative humidity |
Humidity class F |
Yes |
Connection method |
required front connector |
40-pin |
Dimensions |
Width |
160 mm |
Height |
125 mm |
Depth |
118 mm |
Weights |
Weight, approx. |
1 kg |
Status |